Minimum requirements on the air quality:
Air quality to ISO 8573-1:
For dust Class 2 (max. particle size 1µm;
max. particle density 1 mg/m
3
)
For water Class 4 (<=+3 °C pressure dew point)
For oil Class 2 (<=0.1 mg/m3 oil-free)
Recommended air quality:
Air quality to ISO 8573-1:
For dust Class 1 (max.particle size 0.1µm;
max. particle density 0.1mg/m3)
For water Class 4 (<=+3°C pressure dew point)
For oil Class 1 (<=0.01 mg/m3 oil-free)