5. Commissioning
518
Festo GDCP−SFCLACIDN−EN en 0812NH
5.2.6 Teach software end positions
Factory settings by homing method:
Homing method
Factory settings [mm]
Reference switch
(AZ: 0 mm)
SW−limit−neg = 0
SW−limit−pos = (nominal stroke 10)
Negative stop
(AZ: +1 mm)
SW−limit−neg = 0
SW−limit−pos = nominal stroke
Positive stop
(AZ: 1 mm)
SW−limit−neg = (negative) nominal stroke
SW−limit−pos = 0
If necessary, teach the software end positions:
1. Select [Settings] [Axis parameter] [SW−limit−neg] or
[SW−limit−pos].
2. Move the drive with the arrow keys.
Note
During operation, the drive must not strike a stop without
shock absorption.
· Parameterise the software end positions at least 1 mm
from the nearest end stop.
3. Accept the position reached with OK <Enter>. The setting
will th
en take effect.
4. Save the parameter settings in EEPROM with [SAVE]. Only
then will the settings be retained even after switching off
the power
supply or in the event of a power failure.